AD Automatic Drainage SMC
2025/5/23 16:32:07
Automatic drainage, no manual operation required,
Dustproof, durable, and reliable.
Standard parts are equipped with shell covers ranging from 0.1 to 1.0 MPa
AD Automatic Drainage SMC
When there is no pressure inside the water cup, the float (5) descends due to its own weight, and the pressure block (9) closes the inner cavity hole (6),
The piston (8) is pressed down by the spring (11), and the condensed water is drained through (12).
When there is pressure inside the water cup
When the pressure is above 0.1MPa, the piston (8) overcomes the force of the spring (11) and presses upwards, thus draining the water
The channel (12) is closed, and the interior of the water cup (10) is isolated from the outside.
When there is condensed water in the water cup
When the condensed water is collected into a certain program, the float (5) rises due to buoyancy, opens the inner cavity hole (6), and presses
Force enters the inner cavity, the piston (8) is pressed down by pressure and the spring (11), and condensed water flows through the drainage pipe
(13) Drainage.
AD Automatic Drainage SMC
be careful:
1) When installing drainage pipes, an inner diameter of 10 millimeters should be used
The length of the pipe on top should not exceed 5 meters. Do not use it
The pipe bends upwards.
2) The compressor power should be greater than 3.7KW